This genuine ICP defrost control board (OEM part 1069364) is the brain of your YG024GA2 heat pump's defrost system. It monitors coil temperature and run time, then commands a defrost cycle to clear frost and ice from the outdoor coil during heating operation, switching the reversing valve and pausing the outdoor fan as needed. A failed defrost board leads to a coil that ices over and chokes off airflow, sharply reducing heating capacity. Common failure symptoms include a heat pump that frosts up and never defrosts, a unit that defrosts constantly, an outdoor fan that won't restart, or no 24V output to the reversing valve and contactor. Because the board orchestrates the entire heating sequence, replacing a faulty one restores proper defrost timing and protects the compressor.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V AC
Function Heat-pump defrost timing & sequencing
Fitment OEM Replacement

Compatibility

Exact-fit OEM replacement for the ICP/Tempstar/Heil YG024GA2 heat pump and other ICP-family units that use this defrost board. Match the board's part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the control/access panel on the outdoor unit.
  3. Document — Photograph every harness and sensor connection on the board before unplugging anything.
  4. Remove — Unplug all connectors and the defrost/coil sensor, then unscrew or unclip the board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each harness and the sensor per your photo.
  6. Test — Restore power, initiate a heating call, and confirm normal operation and a proper defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never enters defrost.
  • Heat pump defrosts far too often or stays in defrost.
  • Outdoor fan or reversing valve doesn't respond on a heating call.
  • No 24V output from the board to downstream components.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG024GA2 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG024GA2 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG024GA2 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online