Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YG018GB1 — OEM 1069364 24V Heat Pump | Ships Today
ICP

ICP Defrost Control Board for YG018GB1 — OEM 1069364 24V Heat Pump | Ships Today

SKU: 1069364 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM defrost control board (part number 1069364) for the ICP/Heil/Tempstar YG018GB1 heat pump. The defrost board is the brain of the heat pump's defrost cycle: it monitors the outdoor coil temperature and accumulated run time, then commands the reversing valve and outdoor fan to clear frost and ice off the outdoor coil during cold-weather heating. A failed defrost board is one of the most common causes of a heat pump that ices over, blows cold air in heat mode, or short-cycles in winter. Typical symptoms include the outdoor unit freezing solid, the system never entering or never exiting defrost, the auxiliary/emergency heat running constantly, or a unit that hums but won't switch modes. This board operates on a 24V control circuit and replaces the original part exactly for a true plug-and-play fit.

Specifications

Spec Value
Part Number 1069364
Type Defrost Control Board
Brand ICP / Heil / Tempstar / Comfortmaker
Control Voltage 24V
Application Heat Pump Defrost Control
Fit OEM Direct Replacement

Compatibility

Designed as a direct OEM replacement for the ICP-family YG018GB1 heat pump and other Heil, Tempstar, and Comfortmaker units that originally shipped with defrost board 1069364. Always confirm the part number printed on your existing board before ordering, as production runs can vary.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the board terminals with a multimeter.
  2. Access — Remove the outdoor unit's control-panel service cover.
  3. Document — Photograph every wire and connector on the old board before disconnecting anything.
  4. Remove — Label and unplug the low-voltage harness, defrost sensor lead, and any spade connectors, then unscrew the old board from its standoffs.
  5. Install — Mount the new 1069364 board, reconnect every wire to match your photos, and set any defrost-timing jumper/pins to match the original.
  6. Test — Restore power, run the unit in heat mode, and confirm it initiates and terminates a defrost cycle correctly.

Signs You Need a Replacement

  • Outdoor coil ices or frosts over and never clears
  • Heat pump blows cold air or won't switch into defrost
  • Auxiliary/emergency heat runs constantly in cold weather
  • Unit short-cycles or the reversing valve won't energize

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YG018GB1 — OEM 1069364 24V Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YG018GB1 — OEM 1069364 24V Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YG018GB1 — OEM 1069364 24V Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.