This genuine OEM defrost control board (part number 34332101) governs the defrost cycle on the ICP/Heil/Tempstar YE048H heat pump. It monitors the defrost thermostat and outdoor coil temperature, then starts and ends defrost on its timer interval to melt frost and ice from the coil during heating. The board sequences the compressor, reversing valve, and outdoor fan, and brings in auxiliary heat as needed during the cycle. When it fails, the outdoor coil can ice over and block airflow, heating capacity drops, the reversing valve may not switch, or the unit gets stuck in defrost. Living outdoors and exposed to moisture, temperature swings, and voltage surges, the defrost board is a frequent service replacement on aging heat pumps.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24 VAC
Application Heat Pump Defrost
Fit OEM

Compatibility

Directly fits the ICP/Heil/Tempstar YE048H heat pump and related Comfortmaker/Heil-built outdoor units that use board 34332101. Confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the condenser/control-box service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting.
  4. Remove — Unplug connectors, release the standoffs or screws, and lift out the old board.
  5. Install — Seat the new board on its standoffs and reconnect each connector per your photo, matching defrost-time pin settings.
  6. Test — Restore power, run a heating call, and confirm normal operation with proper defrost initiation and termination.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never enters or exits defrost.
  • Heat pump stays stuck in defrost or rapidly cycles the reversing valve.
  • No 24V output to the compressor contactor or fan during a heating call.
  • Visible burn marks, corrosion, or a cracked relay on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YE048H — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YE048H — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YE048H — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.