Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YE024G — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for YE024G — Heat Pump | Ships Today

SKU: 34332101 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM defrost control board (part #34332101) is the brain of the defrost cycle on your ICP YE024G heat pump. It monitors coil temperature and run time, then commands the reversing valve and outdoor fan to clear frost from the outdoor coil during heating. A failed board is one of the most common causes of poor heat-pump heating performance: the outdoor coil ices over, the unit short-cycles, the reversing valve won't switch, or the system gets stuck in (or never enters) defrost. Boards fail from power surges, moisture intrusion, corroded relays, and burnt traces.

Specifications

Spec Value
Part Number 34332101
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Function Defrost timing, reversing valve, fan control
Fitment OEM

Compatibility

Direct-fit replacement for the ICP YE024G heat pump and other ICP-family outdoor units (Heil, Tempstar, Comfortmaker) using the 34332101 defrost board. Match the board's part number and connector layout to your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's control-box cover.
  3. Document — Photograph every wire harness and terminal connection before unplugging.
  4. Remove — Unplug the connectors and unscrew the board from its standoffs.
  5. Install — Mount the new board and reconnect each harness exactly per your photos.
  6. Test — Restore power, run a heating cycle, and confirm proper defrost initiation and termination.

Signs You Need a Replacement

  • Outdoor coil ices up and never defrosts
  • Reversing valve won't switch between heat and cool
  • System short-cycles or stays stuck in defrost
  • Burnt smell, scorched traces, or corroded relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YE024G — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YE024G — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YE024G — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online