The ICP defrost control board (OEM part 34332100) is the brain of the defrost cycle on your YC036GA heat pump. It monitors the outdoor coil temperature sensor and a timing interval, then energizes the reversing valve and stops the outdoor fan to melt frost off the coil during cold-weather operation. When this board fails, the system either never defrosts (coil ices over and heating capacity drops) or defrosts constantly (short cycling, high bills, hot/cold swings indoors). It operates on a 24V control signal and includes the relays and logic that coordinate the compressor, fan, and reversing valve during defrost.

Specifications

Spec Value
Part Number 34332100
Type Defrost Control Board
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24V
Function Time/temperature defrost logic
Fit OEM Replacement

Compatibility

Designed as the factory replacement for the ICP YC036GA heat pump and other Tempstar, Heil, and Comfortmaker units that originally shipped with board 34332100. Always confirm the printed part number on your old board matches before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical access panel.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Label and unplug the low-voltage connectors and sensor leads, then unscrew the failed board from its standoffs.
  5. Install — Mount the new 34332100 board, reconnect each wire exactly per your photo, and seat the defrost sensor securely on the coil tube.
  6. Test — Restore power and force/observe a defrost cycle to confirm the reversing valve and fan respond correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears in heat mode
  • Unit defrosts far too often (short cycling, steam clouds)
  • Reversing valve or outdoor fan won't switch during defrost
  • Visible burnt traces, scorched relays, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YC036GA — Heat Pump Defrost Timer | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YC036GA — Heat Pump Defrost Timer | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YC036GA — Heat Pump Defrost Timer | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.