Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for YA060 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for YA060 — Heat Pump | Ships Today

SKU: YA060 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM defrost control board (part number 1052757) is the brain of the outdoor unit on ICP, Heil, and Tempstar YA060 heat pump systems. In heating mode the board monitors coil temperature and run time, then initiates a defrost cycle to melt frost and ice off the outdoor coil — energizing the reversing valve, stopping the outdoor fan, and timing the cycle so the unit can return to efficient heating. It also coordinates compressor timing and anti-short-cycle protection. When the defrost board fails, the outdoor coil can ice over solid, heating capacity collapses, the unit may short-cycle, or the system won't run at all. Replacing the board restores proper defrost timing and protects the compressor.

Specifications

Spec Value
Part Number 1052757
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24 VAC
Application Heat Pump Defrost Control
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar YA060 heat pump and other ICP-family heat pumps using this defrost control platform. Match the part number 1052757 and connector layout to your existing board before installing, and note any DIP switch / defrost-interval settings.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service/control panel to expose the board.
  3. Document — Photograph all wiring harness connections and record the existing DIP/jumper settings.
  4. Remove — Unplug each connector, release the board's standoffs/screws, and lift it out.
  5. Install — Mount the new board, replicate the DIP/jumper settings, and reconnect every harness per your photo.
  6. Test — Restore power, run a heating cycle, and confirm normal operation and (if forced) a proper defrost cycle.

Signs You Need a Replacement

  • Outdoor coil freezes over and never defrosts
  • Unit stuck in defrost or never enters defrost
  • Heat pump short-cycles or won't start
  • Burn marks, scorching, or corrosion on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP YA060 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP YA060 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP YA060 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online