Overview

This is the genuine OEM defrost control board (part number 1173636) for the ICP/Heil/Tempstar WCH5604GKA200 heat pump. The defrost board monitors outdoor coil temperature and run time, then commands a defrost cycle by reversing the unit and energizing auxiliary heat to melt frost off the outdoor coil. It also manages the reversing valve, compressor timing, and fan delays. When the defrost board fails, the heat pump may ice over solid in cold weather, fail to switch between heating and cooling, short-cycle, or lose heating output entirely.

Specifications

Spec Value
Part Number 1173636
Type Defrost control board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Heat pump defrost / reversing control
Fitment OEM replacement

Compatibility

Factory-correct replacement for the ICP WCH5604GKA200 heat pump and matching Heil, Tempstar, and Comfortmaker outdoor units. Match the board's connector layout and defrost timing pins to your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser control panel cover.
  3. Document — Photograph every connector and the defrost timer pin setting before disconnecting.
  4. Remove — Unplug each harness, release the board standoffs, and lift out the old board.
  5. Install — Seat the new board, set the defrost timer pin to match, and reconnect every harness per your photo.
  6. Test — Restore power and confirm normal heating, then force a defrost cycle to verify reversing-valve and fan operation.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts
  • Heat pump won't switch between heat and cool
  • No auxiliary heat during defrost
  • Short-cycling or no compressor operation

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH5604GKA200 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH5604GKA200 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH5604GKA200 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online