Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for WCH5484GKA100 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for WCH5484GKA100 — Heat Pump | Ships Today

SKU: 1173636 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM defrost control board (part number 1173636) is the brain of the defrost cycle on the ICP / Tempstar / Heil WCH5484GKA100 heat pump. In heating mode, frost builds on the outdoor coil; the defrost board monitors time and coil temperature, then initiates a defrost cycle — energizing the reversing valve, shutting off the outdoor fan, and bringing on auxiliary heat — to melt the ice and restore efficiency. A failed board can leave the outdoor coil iced over (killing heating capacity), run constant or no defrost cycles, or fail to control the reversing valve and fan correctly.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Function Defrost timing, reversing valve & fan control
Application Heat Pump outdoor unit
Fitment OEM

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil WCH5484GKA100 heat pump. The board's defrost logic and terminal layout are specific to this unit's wiring. Confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the control board in the outdoor unit.
  3. Document — Photograph every wire and connector position, and note any dip-switch or jumper settings for defrost timing.
  4. Remove — Disconnect the wiring, release the board from its standoffs, and lift it out.
  5. Install — Mount the new board, match any dip-switch/jumper settings to the original, and reconnect every wire per your photo.
  6. Test — Restore power and verify normal operation; initiate or force a defrost cycle to confirm the reversing valve and fan respond correctly.

Signs You Need a Replacement

  • Outdoor coil iced over and not defrosting in heating mode
  • Defrost cycles run constantly or never initiate
  • Reversing valve or outdoor fan not controlled during defrost
  • No output to the unit despite incoming power

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH5484GKA100 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH5484GKA100 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH5484GKA100 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online