This OEM defrost control board (part #1173636) is the brain that manages the defrost cycle on your ICP WCH5364GKA100 heat pump. In heating mode, frost builds on the outdoor coil; the defrost board monitors coil temperature and elapsed run time, then periodically reverses the system to melt the ice and protect efficiency and the compressor. The board also coordinates the contactor, reversing valve, and fan timing. When a defrost board fails, the outdoor coil ices over solid, heating performance drops, the unit may short-cycle, or it gets stuck in defrost and blows cold air indoors. Because this board sequences several major components, an intermittent failure can mimic problems with the compressor, fan motor, or reversing valve — so confirming the board is at fault before replacing other parts saves time and money.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24 VAC
Application Heat Pump Defrost Cycle
Fitment OEM Replacement

Compatibility

Direct OEM fit for the ICP WCH5364GKA100 heat pump and shared across many ICP-family Tempstar, Heil, and Comfortmaker heat pump condensers using this defrost board.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the control board.
  3. Document — Photograph every wire and connector position on the board before disconnecting.
  4. Remove — Unplug the connectors and defrost sensor, release the board standoffs, and lift out the old board.
  5. Install — Mount the new board on the standoffs and reconnect every wire and the defrost sensor per your photo.
  6. Test — Restore power, initiate heating, and confirm normal operation and a proper defrost sequence.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts
  • Unit stuck in defrost or blowing cold air in heat mode
  • Short-cycling or no response to a heat call
  • No timed defrost initiation despite a frosted coil

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH5364GKA100 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH5364GKA100 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH5364GKA100 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.