This is the OEM defrost control board (part #1173636) for the ICP/Tempstar/Heil WCH460GKA210 heat pump. The defrost board governs the outdoor unit's defrost cycle — it watches coil temperature and accumulated run time, then commands the reversing valve and outdoor fan to melt frost off the condenser coil during heating operation. It also handles compressor anti-short-cycle timing and routes the 24V signals between the thermostat, contactor, and reversing valve. A failed defrost board commonly causes the coil to ice solid, the compressor to lock out, or the unit to run without ever defrosting — problems that look like a refrigerant fault but are really a controls failure.
| Spec | Value |
|---|---|
| Part Number | 1173636 |
| Type | Demand/Timed Defrost Control Board |
| Brand | ICP (Tempstar / Heil) |
| Control Voltage | 24V |
| Fits Model | WCH460GKA210 |
| Fit | OEM Replacement |
Direct OEM fit for the ICP/Tempstar/Heil WCH460GKA210 heat pump and shared ICP-family chassis (Comfortmaker, Arcoaire, KeepRite). Confirm the printed part number on your existing board before ordering.
Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.