This is the OEM defrost control board (part number 1173636) for the ICP / Heil / Tempstar WCH3602GKA1 heat pump. In heating mode the outdoor coil acts as the evaporator and accumulates frost; the defrost control board monitors time and coil temperature, then periodically reverses the system into a short defrost cycle to melt that ice so the unit can keep heating efficiently. The board sequences the reversing valve, condenser fan, and auxiliary/emergency heat during defrost, and protects the compressor with timing logic. When this board fails, the heat pump either never defrosts — letting the outdoor coil ice over into a solid block — or defrosts constantly, blowing cold air indoors and spiking the electric bill.
| Spec | Value |
|---|---|
| OEM Part Number | 1173636 |
| Type | Defrost Control Board |
| Brand | ICP / Heil / Tempstar |
| Control Voltage | 24V |
| Function | Heat Pump Defrost Timing & Sequencing |
| Fits Model | WCH3602GKA1 |
Direct OEM replacement for the WCH3602GKA1 heat pump and the equivalent ICP-family units marketed under Heil, Tempstar, Comfortmaker, and Arcoaire. Defrost boards are model-specific — confirm the part number and connector layout against your existing board before installing.