ICP Defrost Control Board for WCH3602GKA1 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for WCH3602GKA1 — Heat Pump | Ships Today

SKU: 1173636 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM defrost control board (part number 1173636) for the ICP / Heil / Tempstar WCH3602GKA1 heat pump. In heating mode the outdoor coil acts as the evaporator and accumulates frost; the defrost control board monitors time and coil temperature, then periodically reverses the system into a short defrost cycle to melt that ice so the unit can keep heating efficiently. The board sequences the reversing valve, condenser fan, and auxiliary/emergency heat during defrost, and protects the compressor with timing logic. When this board fails, the heat pump either never defrosts — letting the outdoor coil ice over into a solid block — or defrosts constantly, blowing cold air indoors and spiking the electric bill.

Specifications

Spec Value
OEM Part Number 1173636
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Function Heat Pump Defrost Timing & Sequencing
Fits Model WCH3602GKA1

Compatibility

Direct OEM replacement for the WCH3602GKA1 heat pump and the equivalent ICP-family units marketed under Heil, Tempstar, Comfortmaker, and Arcoaire. Defrost boards are model-specific — confirm the part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser control/electrical panel.
  3. Document — Photograph every wire and connector on the old board before unplugging.
  4. Remove — Disconnect harnesses and the defrost thermostat sensor leads; unclip or unscrew the old board.
  5. Install — Mount the new board and reconnect each harness exactly per your photo, including the coil temperature sensor.
  6. Test — Restore power, run a heating call, and verify normal operation; initiate a defrost test if your board supports the speed-up jumper.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts in heating mode
  • Unit goes into defrost constantly, blowing cold air indoors
  • Reversing valve or fan not sequencing during defrost
  • No response on a heating call despite good 24V to the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3602GKA1 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3602GKA1 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3602GKA1 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.