Overview

This is a genuine OEM defrost control board (part #1173636) for the ICP / Heil / Tempstar heat pump model WCH3482GKA1. The defrost board is the brain of the outdoor unit during heating season — it monitors coil temperature and run time, then initiates and terminates the defrost cycle that melts frost off the outdoor coil. It also coordinates the reversing valve, compressor, outdoor fan, and auxiliary heat during defrost. When this 24V board fails, the heat pump cannot clear ice from the coil, efficiency collapses, and the system may lock out or trip on high pressure. Common failure signs include a coil that ices over solid, no defrost cycle, continuous defrost, or no compressor operation in heating mode.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for ICP-family heat pumps including model WCH3482GKA1 and related Heil, Tempstar, and Comfortmaker units that originally shipped with board 1173636. Always verify the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit control-panel service cover.
  3. Document — Photograph every wire and terminal connection before disconnecting anything.
  4. Remove — Label and disconnect all wiring harnesses and sensor leads, then unscrew the failed board from its standoffs.
  5. Install — Mount the new board, transfer the defrost sensor and all connections exactly per your photo, and confirm the defrost timing jumper matches the original (30/60/90 min).
  6. Test — Restore power, run the unit in heating mode, and confirm a normal defrost cycle initiates and terminates correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts
  • Unit gets stuck in continuous defrost
  • No compressor or reversing-valve action in heat mode
  • Visible burn marks, scorched traces, or a failed relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3482GKA1 — 24V Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3482GKA1 — 24V Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3482GKA1 — 24V Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online