Overview

This OEM defrost control board (part 1173636) manages the defrost cycle on the ICP/Heil/Tempstar WCH3304GKA1 heat pump condenser. It monitors coil temperature and accumulated run time, then commands the reversing valve, terminates fan operation, and energizes the outdoor coil to clear frost build-up during heating mode. It also coordinates the compressor time-delay and high/low pressure safety inputs. When this board fails, the unit may run continuously in defrost, never defrost at all (ice on the outdoor coil), short-cycle the compressor, or fail to call for heat. Replacing it with a genuine 24V OEM board restores correct sequencing and protects the compressor.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP / Heil / Tempstar / Comfortmaker
Control Voltage 24V
Application Heat Pump Defrost Control
Fitment OEM Direct Replacement

Compatibility

Engineered as the factory defrost board for the WCH3304GKA1 condensing unit and other ICP-family (Heil, Tempstar, Comfortmaker, Arcoaire) heat pumps using the same control platform. Always confirm the part number on your existing board matches 1173636 before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the board with a multimeter.
  2. Access — Remove the condenser control-panel cover.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Unplug the wiring harnesses and sensor leads, then unscrew the old board from its standoffs.
  5. Install — Mount the new board, reconnect each lead to the matching terminal per your photo, and seat the defrost sensor.
  6. Test — Restore power, initiate a defrost test per the unit instructions, and confirm proper reversing-valve and fan sequencing.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts in heating mode.
  • Unit stays stuck in defrost or short-cycles between modes.
  • No 24V output to the reversing valve or compressor contactor.
  • Visible burn marks, scorched relays, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3304GKA1 — 24V Heat Pump Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3304GKA1 — 24V Heat Pump Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3304GKA1 — 24V Heat Pump Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online