Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for WCH3302GKA1 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for WCH3302GKA1 — Heat Pump | Ships Today

SKU: 1173636 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM defrost control board (OEM part #1173636) for the ICP/Heil/Tempstar WCH3302GKA1 heat pump. The defrost board is the brain of the outdoor unit's heating operation — it monitors the coil temperature sensor and run time, then initiates a defrost cycle to melt ice off the outdoor coil by energizing the reversing valve and pausing the outdoor fan. It also handles compressor timing/anti-short-cycle protection. When this board fails, the heat pump may ice over, fail to defrost, lock out the compressor, or behave erratically in heating mode.

Specifications

Spec Value
OEM Part Number 1173636
Description Defrost Control Board
Type Defrost / Heat Pump Control Board
Brand ICP / Heil / Tempstar / Comfortmaker
Control Voltage 24 VAC
Fits Model WCH3302GKA1

Compatibility

Designed as a direct OEM replacement for the ICP/Heil/Tempstar WCH3302GKA1 heat pump. Defrost boards are model/series specific — match the OEM part number and connector layout before installing, and confirm the coil sensor is compatible.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service/electrical panel.
  3. Document — Photograph every plug and wire position before disconnecting.
  4. Remove — Unplug the connectors, release the standoffs/screws, and lift out the old board.
  5. Install — Mount the new board and reconnect each plug to match your photo and the wiring diagram.
  6. Test — Restore power, run a heating call, and verify normal operation and defrost initiation.

Signs You Need a Replacement

  • Outdoor coil ices up and never defrosts
  • Heat pump won't switch into or out of defrost
  • Compressor lockout or no outdoor unit operation in heat
  • Erratic timing, short cycling, or failed control diagnostics

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3302GKA1 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3302GKA1 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3302GKA1 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online