Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for WCH3244GKA1 — Heat Pump | Ships Today
ICP

ICP Defrost Control Board for WCH3244GKA1 — Heat Pump | Ships Today

SKU: 1173636 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM defrost control board for the ICP / Heil / Tempstar WCH3244GKA1 heat pump. The defrost board is the brain of the outdoor unit's defrost cycle: it monitors the defrost thermostat and time intervals, energizes the reversing valve, stops the condenser fan, and runs the unit briefly in cooling mode to melt frost off the outdoor coil during cold-weather heating. When the defrost board fails, the heat pump can ice over and lose heating capacity, run defrost cycles too often or never at all, fail to start the compressor or fan, or trip on high pressure. Symptoms include a frosted or iced outdoor coil, no defrost cycle, a unit that won't energize the fan or compressor, and erratic mode switching.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24V
Application Heat Pump Defrost Control
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Heil / Tempstar WCH3244GKA1 heat pump condensing unit. This defrost board is used across many ICP-family heat pumps with the same defrost control logic. Match OEM part number 1173636 and the terminal/connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical access panel to expose the control board.
  3. Document — Photograph every wire, plug, and terminal position on the old board before disconnecting.
  4. Remove — Unplug the harnesses, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new defrost board and reconnect every connector exactly per your photo; transfer any jumper/timer settings.
  6. Test — Restore power, run a heating call, and confirm normal operation and a proper forced or timed defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices or frosts over and won't clear
  • No defrost cycle, or defrost runs far too frequently
  • Compressor or condenser fan won't energize
  • Erratic reversing valve / mode switching during heating

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3244GKA1 — Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3244GKA1 — Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3244GKA1 — Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera