Overview

This OEM defrost control board (part #1173636) is the electronic brain of the ICP / Heil / Tempstar WCH3242GKA1 heat pump. It manages the outdoor unit's defrost cycle, monitoring coil temperature and accumulated run time to decide when frost on the outdoor coil must be cleared. When a defrost is needed, the board sequences the reversing valve, shuts down the outdoor fan, and brings on auxiliary heat so the indoor space stays comfortable while the coil thaws. It operates on a 24V control circuit and coordinates the defrost thermostat, time-temperature logic, and safety interlocks. A failed defrost board is a common cause of heat-pump no-heat calls: the unit may become stuck in defrost, ice over solidly in cold weather, fail to switch the reversing valve, or run constantly on expensive emergency heat. Installing the correct OEM board restores reliable, efficient heating performance.

Specifications

Spec Value
Part Number 1173636
Type Defrost Control Board
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Heat Pump Defrost
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP / Heil / Tempstar WCH3242GKA1 heat pump and matching WCH-series condensing units that use the 1173636 defrost board. Compatible across the family of brands built on the same platform, including Comfortmaker and Arcoaire variants. Always confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the outdoor unit control-panel access cover to expose the board.
  3. Document — Photograph every wire connection on the old board before disconnecting anything.
  4. Remove — Label and unplug the harness connectors, release the board mounting clips or screws, and lift out the old defrost board.
  5. Install — Mount the new 1173636 board, then reconnect each terminal and connector exactly as shown in your photo.
  6. Test — Restore power and run a heating cycle; initiate a forced defrost to confirm the reversing valve, fan shutdown, and timing all function.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never defrosts
  • Heat pump stuck in defrost or constantly switching modes
  • No heat-pump heating and the system defaults to emergency/auxiliary heat
  • Reversing valve fails to energize during a defrost cycle

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP WCH3242GKA1 — OEM 1173636 Heat Pump | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP WCH3242GKA1 — OEM 1173636 Heat Pump | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP WCH3242GKA1 — OEM 1173636 Heat Pump | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.