Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Defrost Control Board for RYMA10F001A — Heat Pump OEM 1052757 | Ships Today
ICP

ICP Defrost Control Board for RYMA10F001A — Heat Pump OEM 1052757 | Ships Today

SKU: 1052757 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM defrost control board (part number 1052757) for the ICP RYMA10F001A heat pump. The defrost control board governs the heat pump's defrost cycle — it watches outdoor coil temperature and compressor run time, then switches the system into defrost to melt frost and ice off the outdoor coil during heating operation. A failed board typically shows up as a coil that ices over and loses heat output, a unit stuck in or unable to reach defrost, or excessive auxiliary heat use. The board runs on a 24V control circuit and is matched to the RYMA10F001A platform for correct defrost timing and sensor interpretation.

Specifications

Spec Value
Part Number 1052757
Type Defrost Control Board
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Application Heat Pump
Fits Model RYMA10F001A

Compatibility

Engineered as the direct OEM replacement for the ICP RYMA10F001A heat pump and equivalent Tempstar, Heil, and Comfortmaker units built on the same platform. Confirm the printed part number on your existing board reads 1052757 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the outdoor unit's control access panel.
  3. Document — Photograph every wire and terminal connection on the old board before disconnecting anything.
  4. Remove — Label and disconnect the low-voltage leads and sensor connections, then unclip or unscrew the old board from its standoffs.
  5. Install — Mount the new board, reconnect every wire exactly per your photo, and confirm the defrost sensor is seated on the coil.
  6. Test — Restore power, run a heating call, and verify the unit initiates and terminates defrost correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and never clears in heating mode.
  • Heat pump runs constantly in defrost or never enters defrost.
  • Auxiliary/emergency heat runs excessively, raising electric bills.
  • No response from the board, burnt smell, or visible scorching on the PCB.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RYMA10F001A — Heat Pump OEM 1052757 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RYMA10F001A — Heat Pump OEM 1052757 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RYMA10F001A — Heat Pump OEM 1052757 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online