Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Definite Purpose Contactor Kit (30A/40A/60A 24V) for RHS240L0AA0AAAA | Ships Today
ICP

ICP Definite Purpose Contactor Kit (30A/40A/60A 24V) for RHS240L0AA0AAAA | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM contactor kit covers the 24V definite-purpose contactors used in the ICP/Tempstar/Heil RHS240L0AA0AAAA heat pump: a 2-pole 30-amp (part 1171554), a 3-pole 40-amp (part 1172449), and a 3-pole 60-amp (part 1183374). The contactor is the high-voltage switch that energizes the compressor and condenser fan whenever the 24V control circuit calls. Pitted, welded, or burned contacts are one of the most common causes of a no-cool/no-heat outdoor unit — the fan and compressor either won't start or won't shut off. Each contactor here uses a 24V coil and is a direct OEM-spec replacement.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183374 (3P 60A)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Coil Voltage 24V
Ratings 30A 2-Pole, 40A 3-Pole, 60A 3-Pole
Fits Model RHS240L0AA0AAAA
Fitment OEM Direct Replacement

Compatibility

Direct fit for the ICP/Tempstar/Heil RHS240L0AA0AAAA and equivalent ICP-built units sold under the Tempstar, Heil, Comfortmaker and Arcoaire labels. Select the contactor matching your unit's amp rating and pole count, and confirm with the OEM part number (1171554, 1172449, or 1183374).

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter; the contactor switches line voltage.
  2. Access — Remove the electrical-section service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unbolt the old contactor.
  5. Install — Mount the matching new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power, make a call, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit won't start or won't shut off (welded contacts)
  • Loud buzzing or chattering from the contactor
  • Burned, pitted, or melted contact points
  • 24V coil reads open and the contactor won't pull in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS240L0AA0AAAA | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS240L0AA0AAAA | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS240L0AA0AAAA | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online