This is a genuine OEM 1-pole, 30-amp definite purpose contactor (OEM part #1172472) with an integrated shunt, built for the ICP/Tempstar/Heil WPA3364000RKC1 condensing unit. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor whenever the 24-volt control circuit calls for cooling. When the thermostat closes, 24V is applied to the coil, the magnetic field pulls the armature in, and line voltage passes through the contacts to the load. The built-in shunt provides a continuous current path that keeps the crankcase heater and control circuit energized while the contactor is open. Pitted, burned, or chattering contacts are one of the most common causes of a compressor that hums but won't start, or a condenser fan that runs intermittently. Replacing a worn contactor restores reliable, low-resistance switching and protects the more expensive compressor downstream.

Specifications

Spec Value
OEM Part Number 1172472
Type Definite Purpose Contactor
Poles 1 (Single Pole)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Features Integrated Shunt
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Engineered as the factory replacement contactor for the ICP/Tempstar/Heil model WPA3364000RKC1 split-system condensing unit. The same definite-purpose footprint is used across many ICP-family air conditioners and heat pumps that share a 24V control circuit. Always confirm the OEM part number 1172472 and the 1-pole / 30A / 24V coil rating against the unit you are servicing before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and the breaker, then verify zero voltage at the contactor terminals with a multimeter before touching any wiring.
  2. Access — Remove the condensing unit's electrical access panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting anything.
  4. Remove — Note shunt placement, transfer the wires off the old contactor one at a time, and unbolt it from the bracket.
  5. Install — Mount the new 1172472 contactor, reconnect line, load, and 24V coil leads exactly per your photo, and confirm the shunt is positioned correctly.
  6. Test — Restore power, call for cooling, and verify the contactor pulls in cleanly with the compressor and condenser fan energizing.

Signs You Need a Replacement

  • Compressor hums or buzzes but will not start when cooling is called
  • Burned, pitted, or welded contacts visible on inspection
  • Audible chattering or buzzing from the contactor
  • Condenser fan and compressor cycle intermittently or fail to energize

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP WPA3364000RKC1 — 1-Pole 30A 24V w/ Shunt | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP WPA3364000RKC1 — 1-Pole 30A 24V w/ Shunt | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP WPA3364000RKC1 — 1-Pole 30A 24V w/ Shunt | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online