This OEM definite purpose contactor is the magnetic switch that powers the compressor and condenser fan motor in your ICP / Heil / Tempstar RHS243H0BA0AAAA heat pump. When the thermostat calls, the 24-volt control coil pulls the contactor's contacts closed and feeds line voltage to the compressor. Three OEM options fit this model: a 2-pole 30A (P/N 1171554), a 3-pole 40A (P/N 1172449), and a 3-pole 60A (P/N 1183374). Contactors wear out because their contacts arc and pit on every cycle, eventually welding closed or burning open. Watch for a unit that won't start, a buzzing or chattering contactor, a compressor that runs nonstop even with the thermostat off, or contact points that look black and pitted.
| Spec | Value |
|---|---|
| OEM Part Numbers | 1171554 / 1172449 / 1183374 |
| Type | Definite Purpose Contactor |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Coil Voltage | 24 VAC |
| Poles | 2-Pole & 3-Pole |
| Current Rating | 30A / 40A / 60A |
| Fitment | RHS243H0BA0AAAA |
Directly fits the ICP / Heil / Tempstar RHS243H0BA0AAAA heat pump and the broader ICP-family condensing unit platform. Confirm the pole count, amp rating, and 24V coil of your existing contactor before ordering so the replacement matches your wiring.