These OEM definite-purpose contactors for the ICP / Tempstar / Heil RHS240S0AA0AAAA carry a 24V control coil and are available in three configurations: 2-pole 30A (#1171554), 3-pole 40A (#1172449), and 3-pole 60A (#1183374). The contactor is the high-voltage switch that energizes the compressor and condenser fan whenever the thermostat calls; the 24V coil pulls the contacts closed to pass line voltage to the load. Pitted, welded, or chattering contacts are one of the most common no-cooling and no-heat-pump failures in the field. Choose the pole count and amp rating that matches your existing contactor.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183374 (3P 60A)
Type Definite Purpose Contactor
Coil Voltage 24V
Poles 2-Pole / 3-Pole
Amp Ratings 30A / 40A / 60A
Brand ICP (Tempstar / Heil)
Fits Model RHS240S0AA0AAAA
Fitment OEM Direct Replacement

Compatibility

Fits the ICP Tempstar Heil RHS240S0AA0AAAA and related RHS240 series units. Match the replacement to your original contactor's pole count (2P or 3P) and FLA rating (30A, 40A, or 60A) before ordering.

Installation Guide

  1. Safety First — Disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit service panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Unbolt the old contactor and transfer wires one at a time to avoid mixing them up.
  5. Install — Mount the new contactor, land each wire on the matching terminal per your photos, and torque the lugs.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the compressor/fan energize on a call.

Signs You Need a Replacement

  • Buzzing or chattering contactor on a cooling/heat-pump call
  • Burnt, pitted, or welded contacts
  • Compressor and fan won't start though 24V is present at the coil
  • Visible arcing, melted housing, or stuck plunger

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS240S0AA0AAAA — 30A/40A/60A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS240S0AA0AAAA — 30A/40A/60A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS240S0AA0AAAA — 30A/40A/60A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online