Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Definite Purpose Contactor for RGS243HSFA0AAAA — 30A/40A/60A 24V | Ships Today
ICP

ICP Definite Purpose Contactor for RGS243HSFA0AAAA — 30A/40A/60A 24V | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This listing covers the genuine OEM definite-purpose contactors for the ICP / Tempstar / Heil RGS243HSFA0AAAA package unit: 1171554 (2-pole, 30A), 1172449 (3-pole, 40A), and 1183142 (3-pole, 60A), all with a 24VAC coil. The contactor is the high-amperage switch that energizes the compressor and condenser fan whenever the thermostat calls for cooling. Over time the contact points arc, pit, and weld; the coil can also burn out. The result is a unit that won't start, chatters loudly, or — in the worst case — stays energized with the contacts welded closed. A fresh OEM contactor restores clean, positive switching and protects downstream components.

Specifications

Spec Value
Part Numbers 1171554, 1172449, 1183142
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Coil Voltage 24 VAC
Ratings 2-Pole 30A / 3-Pole 40A / 3-Pole 60A
Fit OEM Direct Replacement

Compatibility

Fits the ICP-family RGS243HSFA0AAAA and equivalent Tempstar, Heil, and Comfortmaker units. Select the pole count and amp rating that match your existing contactor, and verify the 24V coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil leads per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a cooling call.

Signs You Need a Replacement

  • Compressor and fan won't start on a cooling call
  • Loud buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Unit stays running after the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243HSFA0AAAA — 30A/40A/60A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243HSFA0AAAA — 30A/40A/60A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243HSFA0AAAA — 30A/40A/60A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera