Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Definite Purpose Contactor for RGS240HTAA0AAAA - 30/40/60A 24V | Ships Today
ICP

ICP Definite Purpose Contactor for RGS240HTAA0AAAA - 30/40/60A 24V | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

These genuine OEM definite-purpose contactors fit the ICP / Tempstar / Heil RGS240HTAA0AAAA and switch high-voltage line power to the compressor and condenser fan on a 24V control signal. Three factory-correct ratings are available: 1171554 (2-pole, 30A, 24V coil), 1172449 (3-pole, 40A, 24V coil), and 1183142 (3-pole, 60A, 24V coil). When the thermostat calls, the 24V coil pulls the contacts closed to energize the load. Contactors are a high-wear item - the contacts arc every cycle and eventually pit, weld, or fail to pull in. A failing contactor causes no-cool conditions, chattering, or a unit that will not shut off. Installing the exact OEM-rated contactor restores reliable switching.

Specifications

Spec Value
Part Numbers 1171554, 1172449, 1183142
Type Definite purpose contactor
Brand ICP / Tempstar / Heil
Poles 2-pole (30A) / 3-pole (40A & 60A)
Amp Rating 30A / 40A / 60A
Coil Voltage 24 VAC
Fitment OEM exact replacement

Compatibility

Factory-specified contactors for the ICP / Tempstar / Heil RGS240HTAA0AAAA and shared across many related ICP-family condensing units. Match your existing contactor by pole count, amp rating, and 24V coil to select the correct part number (1171554, 1172449, or 1183142).

Installation Guide

  1. Safety First - Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access - Remove the electrical access panel to expose the contactor.
  3. Document - Photograph every line, load, and coil wire before disconnecting.
  4. Remove - Transfer wires one at a time or label them, then unscrew the old contactor from its rail.
  5. Install - Mount the new OEM contactor and reconnect each wire exactly per your photo.
  6. Test - Restore power and confirm the contactor pulls in cleanly and the unit runs.

Signs You Need a Replacement

  • Unit will not start or runs intermittently on a cooling call.
  • Loud buzzing or chattering from the contactor.
  • Pitted, burnt, or welded contacts that stick closed.
  • System will not shut off when the thermostat is satisfied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240HTAA0AAAA - 30/40/60A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240HTAA0AAAA - 30/40/60A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240HTAA0AAAA - 30/40/60A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online