ICP Definite Purpose Contactor for RGS240HRAA0AAAA — 30A/40A/60A 24V | Ships Today
ICP

ICP Definite Purpose Contactor for RGS240HRAA0AAAA — 30A/40A/60A 24V | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite purpose contactor fits the ICP / Heil / Tempstar RGS240HRAA0AAAA system and covers the factory options 1171554 (2-pole, 30A), 1172449 (3-pole, 40A), and 1183142 (3-pole, 60A), all with a 24V control coil. The contactor is the electrically operated switch that closes the high-voltage circuit to the compressor and condenser fan when the 24V thermostat/board signal energizes the coil. Pitted, welded, or chattering contacts are one of the most common causes of a unit that won't start, trips the breaker, or buzzes loudly. A fresh contactor restores clean make-and-break switching and protects the compressor.

Specifications

Spec Value
Part Numbers 1171554, 1172449, 1183142
Type Definite Purpose Contactor
Poles 2-Pole / 3-Pole
Amperage 30A / 40A / 60A
Coil Voltage 24 VAC
Brand ICP / Heil / Tempstar
Fitment OEM Replacement

Compatibility

Fits the ICP / Heil / Tempstar RGS240HRAA0AAAA and related Comfortmaker-family systems. Match the pole count and amp rating of your existing contactor (30A 2-pole, 40A 3-pole, or 60A 3-pole) before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor from its rail or bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan energize on a cooling call.

Signs You Need a Replacement

  • Loud buzzing or chattering at the contactor
  • Pitted, burnt, or welded-shut contacts
  • Compressor or fan won't start, or runs after the call ends
  • Breaker trips on startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240HRAA0AAAA — 30A/40A/60A 24V | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240HRAA0AAAA — 30A/40A/60A 24V | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240HRAA0AAAA — 30A/40A/60A 24V | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online