Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHX048K0XA0AAA — Heat Pump Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHX048K0XA0AAA — Heat Pump Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the electronic brain of the ICP RHX048K0XA0AAA heat pump. Operating on the 24-volt control circuit, the board manages defrost timing and termination, energizes the reversing valve and contactor, sequences the outdoor fan, and provides safety lockouts that protect the compressor from short-cycling and pressure faults. Supplied as a complete kit with the mounting hardware and connector harness needed for a clean swap, it restores reliable heat-pump operation when the original board has failed. Common failure symptoms include no outdoor unit operation, the system stuck in or out of defrost, ice buildup on the coil in heating mode, a fan that runs constantly or not at all, and erratic switching between heating and cooling. Board failures are frequently caused by power surges, lightning, moisture intrusion, and overheated relays.

Specifications

Spec Value
OEM Part Number 1183618
Type Defrost / Timing Control Board Kit
Brand ICP / Tempstar / Heil / Comfortmaker
Control Voltage 24V
Includes Board, mounting hardware, connectors
Application Heat Pump Outdoor Unit

Compatibility

A direct OEM replacement kit for the ICP RHX048K0XA0AAA heat pump and the matching Tempstar, Heil, and Comfortmaker outdoor units that use this defrost control platform. Verify the part number on the existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit's electrical control panel.
  3. Document — Photograph every wire and connector on the old board before removing anything.
  4. Remove — Unplug the harness connectors, remove the mounting screws or standoffs, and lift out the failed board.
  5. Install — Mount the new board with the supplied hardware and reconnect each plug to match your photo.
  6. Test — Restore power, run a heating and a cooling cycle, and confirm proper defrost and reversing-valve operation.

Signs You Need a Replacement

  • Outdoor unit is completely unresponsive on a call for heat or cool.
  • Heavy ice or frost on the outdoor coil because defrost never initiates.
  • System stuck in defrost or constantly switching modes.
  • Burnt smell, scorched relays, or visible damage on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHX048K0XA0AAA — Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHX048K0XA0AAA — Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHX048K0XA0AAA — Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera