Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS243L0AA0AAAA — 24V Defrost Control | Ships Today
ICP

ICP Control Board Kit for RHS243L0AA0AAAA — 24V Defrost Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Control Board Kit (Part No. 1183618) is the electronic control center for the ICP / Tempstar / Heil RHS243L0AA0AAAA heat pump. It governs the defrost cycle, reads temperature and pressure inputs, and sequences the compressor contactor and reversing valve on a 24V circuit. A failed board can leave the unit running endlessly in defrost, unable to switch between heating and cooling, short-cycling the compressor, or unresponsive to thermostat calls. Installing the factory board kit restores correct timing and built-in protective logic.

Specifications

Spec Value
Part Number 1183618
Type Control Board Kit (Defrost / Sequencing)
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fit OEM Replacement

Compatibility

Designed for the ICP RHS243L0AA0AAAA heat pump and shared across the RHS243 platform sold under the ICP, Tempstar, Heil, and Comfortmaker brands. Confirm your unit's data-plate model and the existing board's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-panel service cover on the condensing unit.
  3. Document — Photograph every wire and connector on the old board before disconnecting.
  4. Remove — Unplug the low-voltage harness and line connections, release the standoffs, and lift out the failed board.
  5. Install — Seat the new board on the standoffs and reconnect each wire exactly per your photos.
  6. Test — Restore power, run a heating and a cooling call, and confirm a normal defrost cycle.

Signs You Need a Replacement

  • Unit stuck in defrost or never defrosts
  • No response to thermostat heat/cool calls
  • Compressor short-cycling or failing to start
  • Burnt, scorched, or swollen components on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS243L0AA0AAAA — 24V Defrost Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS243L0AA0AAAA — 24V Defrost Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS243L0AA0AAAA — 24V Defrost Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.