Overview

This OEM control board kit (P/N 1183618) is the electronic brain of your ICP / Heil / Tempstar RHS243H0CA0AAAA heat pump. It manages the defrost cycle, compressor and reversing-valve timing, fan sequencing, and the safety lockouts that protect the system. The board reads the defrost thermostat and timer settings to decide when to melt frost off the outdoor coil during heating, then returns the unit to normal operation. Because it carries 24V control logic and switches relays under load, the board is vulnerable to power surges, lightning, moisture intrusion, and simple age. Common failure symptoms include a heat pump that won't switch between heating and cooling, no defrost (coil iced over), erratic compressor cycling, blank or no diagnostic LED, or burned/scorched traces on the board itself.

Specifications

Spec Value
OEM Part Number 1183618 (Kit)
Type Defrost / Heat Pump Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24 VAC
Function Defrost, compressor & reversing-valve sequencing
Fitment RHS243H0CA0AAAA

Compatibility

Engineered for the ICP / Heil / Tempstar RHS243H0CA0AAAA heat pump. This is a factory kit, so it includes the board and the hardware needed for a direct replacement. Match the OEM part number on your existing board before ordering — control boards vary by model and revision.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access – Remove the condenser control-box cover to reach the board.
  3. Document – Photograph every wire and connector position before unplugging anything.
  4. Remove – Unplug the harnesses, release the board standoffs/screws, and lift out the old board.
  5. Install – Seat the new board on the standoffs and reconnect each harness exactly per your photo; set any dip switches/jumpers to match the original.
  6. Test – Restore power, run a heating and cooling call, and confirm proper defrost and changeover operation.

Signs You Need a Replacement

  • Outdoor coil icing over with no defrost cycle
  • Unit won't switch between heat and cool
  • Erratic or short compressor cycling
  • Visible burn marks, corrosion, or a dead diagnostic LED

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS243H0CA0AAAA – OEM Defrost/Heat Pump Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS243H0CA0AAAA – OEM Defrost/Heat Pump Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS243H0CA0AAAA – OEM Defrost/Heat Pump Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.