Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS240L0EA0AAAA — 24V Heat Pump Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHS240L0EA0AAAA — 24V Heat Pump Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (OEM 1183618) for the ICP / Heil / Tempstar RHS240L0EA0AAAA heat pump is the brain of the outdoor unit's defrost and control logic. It manages the defrost cycle timing, monitors the coil and ambient sensors, switches the reversing valve, and sequences the compressor and condenser fan. Supplied as a complete kit with the mounting hardware and connectors needed for a clean replacement. A failed control board is a common cause of no-heat in heat-pump mode, ice buildup on the outdoor coil from missed defrost cycles, intermittent operation, and erratic compressor or fan behavior.

Specifications

Spec Value
Part Number 1183618
Type Defrost / Control Board Kit
Brand ICP / Heil / Tempstar
Control Voltage 24V
Supplied As Complete Kit
Fit OEM

Compatibility

Built for the ICP RHS240L0EA0AAAA split heat pump and shared-platform outdoor units sold under the Heil, Tempstar, Comfortmaker, and Arcoaire labels. Verify the OEM kit number against your existing board before ordering, as control boards are platform-specific.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the outdoor unit control panel cover.
  3. Document — Photograph every harness and sensor connection on the old board.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new kit board and reconnect every harness to its matching plug per your photo.
  6. Test — Restore power, run a heat call, and confirm normal sequencing and a proper defrost cycle.

Signs You Need a Replacement

  • Heavy ice buildup on the outdoor coil from missed defrost cycles.
  • No heat in heat-pump mode despite a thermostat call.
  • Compressor or fan short-cycling or random shutdowns.
  • Visible burn marks, scorching, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS240L0EA0AAAA — 24V Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS240L0EA0AAAA — 24V Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS240L0EA0AAAA — 24V Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online