Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS183H0CA0AAAA — OEM Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHS183H0CA0AAAA — OEM Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the electronic brain of your ICP RHS183H0CA0AAAA heat pump. It manages the defrost cycle, energizes the reversing valve to switch between heating and cooling, sequences the compressor contactor, and times the condenser fan. The kit ships with the mounting hardware and connectors needed for a clean replacement. Control boards fail from power surges, lightning, moisture intrusion, and simple age — burned relay traces and cracked solder joints are common. When the board goes, symptoms range from a heat pump stuck in defrost, to ice buildup on the outdoor coil, to no heating or cooling at all despite a good thermostat signal. A scorched spot or blown relay visible on the board confirms it.

Specifications

Spec Value
OEM Part Number 1183618
Type Defrost / Heat Pump Control Board Kit
Brand ICP / Heil / Tempstar / Comfortmaker
Control Voltage 24V
Functions Defrost, reversing valve, compressor, fan timing
Includes Board, connectors, mounting hardware
Fit Direct OEM Replacement

Compatibility

Direct-fit replacement kit for the ICP RHS183H0CA0AAAA heat pump and the ICP-built Heil, Tempstar, and Comfortmaker units that share this control board. Verify the original board part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the board terminals with a multimeter.
  2. Access — Remove the control-panel service cover on the outdoor unit.
  3. Document — Photograph every harness and plug position on the board before disconnecting.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift the old board out.
  5. Install — Mount the new board on the supplied standoffs and reconnect each harness exactly per your photo and the wiring diagram.
  6. Test — Restore power, confirm a normal startup, and verify the unit heats, cools, and exits defrost correctly.

Signs You Need a Replacement

  • Outdoor coil ices over and the unit never defrosts
  • Heat pump stuck running in defrost mode
  • No heating or cooling despite a valid thermostat call
  • Visible scorch marks or a blown relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS183H0CA0AAAA — OEM Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS183H0CA0AAAA — OEM Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS183H0CA0AAAA — OEM Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online