Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS181L0CA0AAAA — Heat Pump Defrost Control | Ships Today
ICP

ICP Control Board Kit for RHS181L0CA0AAAA — Heat Pump Defrost Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (ICP part 1183618) is the electronic brain of your ICP RHS181L0CA0AAAA heat pump. It manages the defrost cycle, reversing-valve sequencing, compressor timing, and the 24V control logic that ties the outdoor unit to the indoor air handler and thermostat. When this board fails, the system may stop heating or cooling, get stuck in or skip defrost, ice over the outdoor coil, or behave erratically. The kit ships with the replacement board and the mounting hardware needed for a clean swap.

Specifications

Spec Value
Part Number 1183618
Type Control Board Kit (Defrost / Sequencing)
Brand ICP / Heil / Tempstar
Control Voltage 24V
Application Heat Pump Outdoor Unit
Fit OEM Replacement Kit

Compatibility

Designed for the ICP / Tempstar / Heil / Comfortmaker RHS181L0CA0AAAA heat pump and compatible RHS181 series units calling for control board kit 1183618. Confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical control panel cover.
  3. Document — Photograph every wire and connector on the board before removing anything.
  4. Remove — Label and unplug the low- and line-voltage harnesses, then unscrew the board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a heating and cooling call, and verify a normal defrost cycle.

Signs You Need a Replacement

  • No heating or cooling despite a good thermostat call
  • Outdoor coil icing because defrost never initiates
  • Unit stuck in defrost or short-cycling the compressor
  • Visible burn marks, corrosion, or cracked solder on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS181L0CA0AAAA — Heat Pump Defrost Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS181L0CA0AAAA — Heat Pump Defrost Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS181L0CA0AAAA — Heat Pump Defrost Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.