Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS181H0AA0AAAA — Defrost/Heat Pump Control | Ships Today
ICP

ICP Control Board Kit for RHS181H0AA0AAAA — Defrost/Heat Pump Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit is the electronic brain of your ICP RHS181H0AA0AAAA heat pump's outdoor section. It manages the defrost cycle, reversing valve sequencing, compressor timing/anti-short-cycle delays, and fan operation based on inputs from the defrost thermostat and the indoor control. When the board fails, the heat pump loses the logic that keeps the outdoor coil ice-free in heating mode and protects the compressor between cycles. Boards typically fail from voltage surges, lightning, moisture intrusion, corroded relays, or burned solder traces around the relay contacts. Symptoms include a heat pump that won't defrost (heavy ice on the outdoor coil), no heating or no cooling, the compressor short-cycling, the reversing valve not switching modes, or no response at all from the outdoor unit. This kit ships as a complete OEM assembly so you replace the whole board rather than chasing individual relays.

Specifications

Spec Value
Part Number 1183618
Type Defrost / Heat Pump Control Board Kit
Brand ICP (Heil / Tempstar)
Control Voltage 24 VAC
Functions Defrost timing, reversing valve, compressor delay
Fit OEM Direct Replacement Kit

Compatibility

Designed as a direct OEM fit for the ICP / Heil / Tempstar / Comfortmaker RHS181H0AA0AAAA heat pump. The 1183618 kit replaces the original defrost control assembly on this model and compatible RHS-series single-stage heat pumps. Confirm your unit uses a defrost control board (not a mechanical timer) before ordering.

Installation Guide

  1. Safety First — Shut off power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical/control access panel.
  3. Document — Photograph every wire and connector on the board, noting terminal labels.
  4. Remove — Unplug the harness connectors and remove the board mounting screws or standoffs.
  5. Install — Mount the new board kit and reconnect each connector and wire exactly per your photo; set any defrost timing jumper to match the original.
  6. Test — Restore power and confirm normal heat, cool, and a forced or timed defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over and never defrosts in heating mode
  • No heat, no cool, or compressor short-cycling
  • Reversing valve fails to switch between heat and cool
  • Burnt smell, scorched relay, or corroded traces on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS181H0AA0AAAA — Defrost/Heat Pump Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS181H0AA0AAAA — Defrost/Heat Pump Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS181H0AA0AAAA — Defrost/Heat Pump Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online