Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHS150L0CB0AAAA — 24V Integrated Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHS150L0CB0AAAA — 24V Integrated Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the central logic board for the ICP / Heil / Tempstar RHS150L0CB0AAAA heat pump. It manages the 24V control circuit, sequences the compressor and condenser fan, and governs defrost timing for reliable heat-pump operation in both heating and cooling modes. When this board fails the unit may stop responding to thermostat calls, run continuously, fail to enter or exit defrost, or trip on safety lockouts. A faulty board often shows scorched relay contacts, blown traces, or a board that no longer powers up. Replacing it with the genuine OEM kit restores correct timing and protection rather than masking a symptom.

Specifications

Spec Value
Part Number 1183618 (KIT CONTROL BOARD)
Type Integrated heat-pump / defrost control board
Brand ICP (Heil / Tempstar)
Control Voltage 24V
Fits Model RHS150L0CB0AAAA
Fitment OEM direct replacement

Compatibility

Engineered as a direct-fit replacement for the ICP / Heil / Tempstar RHS150L0CB0AAAA heat pump and closely related RHS150-series units that originally shipped with the 1183618 board kit. Always confirm your existing board's part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the board's line terminals.
  2. Access — Remove the unit's control/service panel to expose the existing board.
  3. Document — Photograph every wire and connector position before disconnecting anything.
  4. Remove — Label and unplug the low-voltage harness, sensor leads, and high-voltage terminals, then unsnap or unscrew the old board from its standoffs.
  5. Install — Mount the new 1183618 board on the standoffs and reconnect each wire exactly as photographed.
  6. Test — Restore power, call for heat and cool, and confirm correct staging, fan operation, and a clean defrost cycle.

Signs You Need a Replacement

  • Unit does not respond to thermostat calls or runs continuously.
  • Heat pump fails to enter or exit defrost properly.
  • Visible burnt relays, scorched traces, or a dead board with no LED.
  • Intermittent lockouts or erratic compressor/fan cycling.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHS150L0CB0AAAA — 24V Integrated Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHS150L0CB0AAAA — 24V Integrated Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHS150L0CB0AAAA — 24V Integrated Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera