Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHH102S0BA0AAAA — OEM Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHH102S0BA0AAAA — OEM Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the electronic brain of the ICP RHH102S0BA0AAAA heat pump. It manages defrost cycle timing, reversing valve sequencing, compressor and fan staging, and the 24V control logic that ties the thermostat, contactor, and sensors together. When a control board fails, symptoms range from no operation at all to erratic behavior — ice buildup on the outdoor coil from missed defrost cycles, the unit short-cycling, or stages failing to energize. Supplied as a complete OEM kit for a clean, direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Defrost / Control Board Kit
Brand ICP
Control Voltage 24V
Application Heat Pump Control / Defrost

Compatibility

Designed for the ICP / Tempstar / Heil RHH102S0BA0AAAA heat pump and equivalent units using this control board platform. Confirm the board part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control-box access panel.
  3. Document — Photograph every plug, terminal, and wire color on the old board before disconnecting.
  4. Remove — Unplug the harnesses, release the standoffs/screws, and lift out the old board.
  5. Install — Seat the new board on its standoffs and reconnect each harness to its matching plug per your photo.
  6. Test — Restore power, run a heat and cool call, and verify defrost initiation/termination.

Signs You Need a Replacement

  • Outdoor coil icing over from missed defrost cycles
  • Unit fails to start or short-cycles
  • Reversing valve or stages not energizing on demand
  • No control-board status LED or an error/fault flash code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH102S0BA0AAAA — OEM Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH102S0BA0AAAA — OEM Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH102S0BA0AAAA — OEM Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.