Overview

This genuine OEM control board kit (P/N 1183618, KIT CONTROL BOARD) is the electronic brain of the ICP / Heil / Tempstar RHH072L0BA0AAAA heat pump. It manages the defrost cycle, compressor and reversing-valve timing, anti-short-cycle protection, and the 24V control signals that coordinate the indoor and outdoor equipment. As a complete kit it ships with the board and the mounting/connector hardware needed for a clean swap. A failed control board is one of the most common causes of erratic heat pump behavior: the unit may stop defrosting and ice over, fail to switch between heating and cooling, short-cycle the compressor, or go completely dead with no response to a thermostat call. Burnt traces, blown relays on the board, scorched connectors, and no LED status activity all point to board failure. This direct-replacement kit restores correct sequencing and protection logic to keep the system running efficiently through every season.

Specifications

Spec Value
Part Number 1183618
Type Control / Defrost Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Control Voltage 24 VAC
Includes Board plus mounting and connector hardware
Fitment OEM direct replacement

Compatibility

Engineered for the ICP / Heil / Tempstar RHH072L0BA0AAAA heat pump and other RHH072-series outdoor units calling out control board kit P/N 1183618. Confirm the OEM part number printed on the existing board before ordering, as board revisions vary by series.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the board with a multimeter.
  2. Access — Remove the service panel to expose the control box and existing board.
  3. Document — Photograph every harness plug and terminal position before disconnecting; note any dip-switch or jumper settings.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new board on the supplied standoffs, match any dip-switch/jumper settings, and reconnect every harness per your photo.
  6. Test — Restore power, watch for normal LED status, and run heat, cool, and a forced defrost to confirm correct operation.

Signs You Need a Replacement

  • Heat pump ices over and never enters defrost
  • No response to thermostat calls / dead control circuit
  • Compressor short-cycling or random shutdowns
  • Burnt traces, blown on-board relays, or no LED activity

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH072L0BA0AAAA — Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH072L0BA0AAAA — Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH072L0BA0AAAA — Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online