This is the genuine OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RHH060H0CA0AAAA heat pump. The control board is the brain of the outdoor unit — it manages the defrost cycle, reversing valve operation, compressor timing, and safety lockouts. When this board fails the system may stop heating in defrost weather, run continuously, ice over, or refuse to start the compressor entirely. Replacing the board with the correct OEM kit restores proper sequencing and protects the compressor from short-cycling.

Specifications

Spec Value
Part Number 1183618
Type Control / Defrost Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fits Model RHH060H0CA0AAAA
Fitment OEM Direct Replacement

Compatibility

Engineered specifically for the ICP / Tempstar / Heil RHH060H0CA0AAAA heat pump and closely related RHH060 series outdoor units. Always confirm the printed part number on your existing board matches 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the board terminals.
  2. Access — Remove the outdoor unit control-panel access cover.
  3. Document — Photograph every wire and connector landing before disconnecting anything.
  4. Remove — Unplug the harness connectors, release the board standoffs/screws, and lift out the failed board.
  5. Install — Seat the new 1183618 board on the standoffs and reconnect each harness exactly per your photo, setting any defrost-time jumper to match the original.
  6. Test — Restore power and confirm proper startup, reversing-valve operation, and defrost initiation/termination.

Signs You Need a Replacement

  • Heat pump ices over and never enters or exits defrost
  • Compressor or reversing valve will not energize
  • System short-cycles or locks out intermittently
  • Visible burn marks, swollen relays, or scorched traces on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH060H0CA0AAAA — OEM 1183618 Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH060H0CA0AAAA — OEM 1183618 Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH060H0CA0AAAA — OEM 1183618 Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.