Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHH048S0XA0AAAA — OEM Heat Pump Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHH048S0XA0AAAA — OEM Heat Pump Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618, KIT CONTROL BOARD) is the electronic brain of the ICP / Tempstar / Heil RHH048S0XA0AAAA 4-ton heat pump. The board manages defrost timing and termination, anti-short-cycle delays, reversing valve and contactor energizing, and the condenser fan and compressor sequencing in response to thermostat and sensor inputs. Supplied as a complete kit with the hardware and connectors needed for a clean swap. When the board fails, the heat pump may not start, may stay locked in defrost, ice over the outdoor coil, fail to switch between heat and cool, or trip on safety lockouts. Replacing a failed board restores correct timing and sequencing across the entire system.

Specifications

Spec Value
Part Number 1183618
Type Heat Pump Defrost / Control Board Kit
Control Voltage 24 Volt
Brand ICP (Tempstar / Heil)
Supplied As Complete Replacement Kit
Fitment OEM

Compatibility

Built for the RHH048S0XA0AAAA heat pump and matching ICP-family Tempstar, Heil, and Comfortmaker heat pumps that use this control board kit. Match your existing board part number or kit reference before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the service panel to reach the control box and board mount.
  3. Document — Photograph every wire harness, plug, and sensor connection before disconnecting.
  4. Remove — Unplug the harnesses, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board from the kit, transfer connections one at a time per your photo, and set any jumpers or defrost timing to match the original.
  6. Test — Restore power, run heat and cool modes, and confirm normal sequencing and defrost operation.

Signs You Need a Replacement

  • Heat pump won't start or randomly shuts down
  • Outdoor coil ices over or unit stuck in defrost
  • No switching between heating and cooling
  • Burn marks, swollen components, or relay clicking with no output

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH048S0XA0AAAA — OEM Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH048S0XA0AAAA — OEM Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH048S0XA0AAAA — OEM Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online