Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHH048S0BA0AAAA — 24V Heat Pump Defrost Board | Ships Today
ICP

ICP Control Board Kit for RHH048S0BA0AAAA — 24V Heat Pump Defrost Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the electronic brain of the ICP/Heil/Tempstar RHH048S0BA0AAAA heat pump. It manages defrost timing and termination, compressor staging, reversing valve switching, and fan operation based on inputs from the thermostat and the outdoor coil sensor. Supplied as a complete kit, it includes the board and the hardware needed for a clean swap. Control boards fail from voltage surges, lightning, corrosion, heat stress, and aged relays. Common symptoms include a heat pump that won't go into or out of defrost, ice buildup on the outdoor coil, no compressor or fan operation, intermittent lockouts, or no response to a thermostat call at all.

Specifications

Spec Value
Part Number 1183618
Type Control Board Kit (Defrost / Sequencing)
Brand ICP (Heil / Tempstar)
Control Voltage 24V
Fits Model RHH048S0BA0AAAA

Compatibility

Direct OEM replacement kit for the ICP/Heil/Tempstar RHH048S0BA0AAAA heat pump and other units in the same family that use this defrost control platform. Because control boards are revision-specific, verify the part number on your existing board matches 1183618 or its superseding kit before installing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the condenser electrical service panel to expose the control board.
  3. Document — Photograph every wire, plug, and sensor connection on the existing board before disconnecting.
  4. Remove — Unplug the harnesses and sensor leads, release the board standoffs or screws, and lift the old board out.
  5. Install — Seat the new board on the standoffs, reconnect each harness and sensor exactly per your photo, and set any jumpers/dip switches to match the old board.
  6. Test — Restore power and run a heating and cooling cycle; verify normal startup, reversing valve action, and a manual or forced defrost cycle.

Signs You Need a Replacement

  • Outdoor coil ices over because defrost never initiates or terminates
  • No compressor or outdoor fan operation despite a thermostat call
  • Intermittent lockouts, error codes, or random shutdowns
  • Visible burn marks, corrosion, or a burnt-electronics smell on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH048S0BA0AAAA — 24V Heat Pump Defrost Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH048S0BA0AAAA — 24V Heat Pump Defrost Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH048S0BA0AAAA — 24V Heat Pump Defrost Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online