Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RHH036S0CA0AAAA — OEM Defrost/Heat Pump Board | Ships Today
ICP

ICP Control Board Kit for RHH036S0CA0AAAA — OEM Defrost/Heat Pump Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the brain of your ICP (Tempstar/Heil) RHH036S0CA0AAAA heat pump. It manages the defrost cycle, sequences the compressor and reversing valve, monitors sensors, and protects the system with built-in timing and lockout logic. Control boards fail from voltage spikes, lightning, moisture, heat stress, and aged solder joints. When the board goes bad, you may see no defrost cycle, a unit that won't respond to the thermostat, the system stuck in one mode, error or fault LEDs, or no output to the compressor and fan.

Specifications

Spec Value
Part Number 1183618
Type Defrost / Heat Pump Control Board Kit
Brand ICP (Tempstar / Heil)
Includes Board + mounting/connector hardware
Fitment OEM

Compatibility

Designed for the ICP/Tempstar/Heil RHH036S0CA0AAAA 3-ton heat pump and matched RHH036 series units. Compare the OEM part number and connector layout to your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment panel.
  3. Document — Photograph every plug and harness location before unplugging the old board.
  4. Remove — Unplug each connector, release the board standoffs or screws, and lift the board out.
  5. Install — Mount the new board on the standoffs and reconnect every harness to its matching socket per your photo.
  6. Test — Restore power, watch the diagnostic LED, and verify normal heating, cooling, and defrost operation.

Signs You Need a Replacement

  • No defrost cycle in heating mode
  • System unresponsive to thermostat calls
  • Fault or error LED flashing on the board
  • No output to compressor or fan despite a valid call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RHH036S0CA0AAAA — OEM Defrost/Heat Pump Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RHH036S0CA0AAAA — OEM Defrost/Heat Pump Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RHH036S0CA0AAAA — OEM Defrost/Heat Pump Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online