Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGX060KRCA0AAA — OEM Furnace Ignition Control 1183618 | Ships Today
ICP

ICP Control Board Kit for RGX060KRCA0AAA — OEM Furnace Ignition Control 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace ignition control for the ICP / Heil / Tempstar RGX060KRCA0AAA gas furnace. The board is the brain of the furnace — it sequences the draft inducer, energizes the hot surface igniter, opens the gas valve, monitors the flame sensor, controls the blower, and reads the pressure and limit switches. A failed control board can leave the furnace completely dead, stuck in lockout, short-cycling, or running the blower continuously. This kit ships as a complete replacement assembly with the mounting and connector hardware needed for a clean swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Ignition Control Board Kit
Brand ICP / Heil / Tempstar
Voltage 120V Primary
Application Gas Furnace Control
Fit OEM Direct Replacement Kit

Compatibility

Designed as the exact-fit control board kit for the ICP / Heil / Tempstar / Comfortmaker RGX060KRCA0AAA gas furnace. This board platform is shared across multiple RGX-series and related Heil-built furnaces. Match the part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting — terminal layout is critical.
  4. Remove — Unplug all harness connectors, remove the board mounting screws/standoffs, and lift the old board out.
  5. Install — Mount the new board, then transfer each connector exactly per your photos.
  6. Test — Restore gas and power, set the thermostat to heat, and verify a full ignition sequence and blower operation with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive on a heat call.
  • Repeated lockouts or erratic short-cycling.
  • Blower runs continuously or fails to start.
  • Visible burnt traces, scorch marks, or a blown fuse on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGX060KRCA0AAA — OEM Furnace Ignition Control 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGX060KRCA0AAA — OEM Furnace Ignition Control 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGX060KRCA0AAA — OEM Furnace Ignition Control 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online