Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGX060KMCA0AAA Gas Furnace — OEM 1183618 | Ships Today
ICP

ICP Control Board Kit for RGX060KMCA0AAA Gas Furnace — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM integrated furnace control board kit (Part No. 1183618) for the ICP / Heil / Tempstar RGX060KMCA0AAA gas furnace. The control board is the brain of the furnace — it manages the ignition sequence, monitors safety circuits (pressure switch, limit switch, flame sensor), sequences the inducer and blower motors, and handles thermostat calls for heat. When this board fails, the furnace will not run reliably: you may see no ignition, short cycling, a constantly running blower, or flashing diagnostic LED fault codes. Replacing a failed board with a genuine OEM kit restores proper, code-compliant operation and protects the downstream components.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGX060KMCA0AAA
Application Gas Furnace
Fitment OEM Direct Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP / Heil / Tempstar RGX060KMCA0AAA gas furnace. This is the same control kit specified by the manufacturer for this model, so it matches the original wiring harness, plug locations, and ignition timing. Always confirm the part number printed on your existing board before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire connector and plug on the existing board before disconnecting anything.
  4. Remove — Unplug all low-voltage and line-voltage harness connectors, release the board mounting tabs/screws, and lift out the failed control board.
  5. Install — Mount the new 1183618 board, then reconnect each harness plug exactly per your photos.
  6. Test — Restore gas and power, run a heat call, and confirm a normal ignition sequence with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace does not respond to a thermostat call for heat
  • Blower or inducer runs continuously or fails to start
  • Flashing diagnostic LED fault codes pointing to control failure
  • Intermittent ignition lockouts or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGX060KMCA0AAA Gas Furnace — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGX060KMCA0AAA Gas Furnace — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGX060KMCA0AAA Gas Furnace — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online