Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS303SDFA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS303SDFA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM control board kit, ICP part number 1183618, for the ICP / Tempstar / Heil RGS303SDFA0AAAA gas furnace. The integrated furnace control board is the brain of the unit — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety circuits such as limit and pressure switches, and reads the thermostat call. The kit includes the board and mounting hardware needed for a complete replacement. When the board fails, the furnace may fail to ignite, lock out, run the blower continuously, throw repeated fault codes, or go completely dead even with power present.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Includes Control board + mounting hardware
Function Ignition, blower/inducer sequencing, safety monitoring
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS303SDFA0AAAA gas furnace and related ICP-family units that use the 1183618 control board kit. Match the part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to reach the control board.
  3. Document — Photograph every harness connector and wire location on the board before disconnecting.
  4. Remove — Unplug each harness, release the board from its standoffs, and lift it out.
  5. Install — Mount the new board with the included hardware and reconnect every harness exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead despite confirmed power.
  • No ignition or repeated lockouts with no other faulty component.
  • Blower runs continuously or will not start.
  • Repeated or erratic LED fault codes from the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303SDFA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303SDFA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303SDFA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online