Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP Tempstar Heil RGS303HFAA0AAAA furnace. The integrated furnace control board is the brain of the system — it sequences ignition, manages the inducer and blower, monitors safety limits and flame, and processes the thermostat signal. When the board fails you may see no response to a heat call, blower or inducer that won't run, erratic short-cycling, or fault codes flashed on the diagnostic LED. The 1183618 kit ships with the matching board and mounting hardware so you can restore full furnace operation with an exact OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Fits Model RGS303HFAA0AAAA
Function Ignition, blower, inducer & safety control
Fitment OEM exact replacement kit

Compatibility

Direct OEM replacement for the ICP Tempstar Heil RGS303HFAA0AAAA furnace and related RGS-series units that specify the 1183618 control board kit. Confirm your existing board part number and connector layout before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every connector and wire harness on the old board before unplugging anything.
  4. Remove — Unplug each harness, remove the board mounting screws, and lift out the failed board.
  5. Install — Mount the new board from the kit, transfer any jumpers/settings, and reconnect each harness per your photo.
  6. Test — Restore power, run a full heat cycle, and confirm ignition, inducer, blower, and diagnostic LED operate normally.

Signs You Need a Replacement

  • No response from the furnace on a thermostat heat call.
  • Inducer or blower motor will not energize.
  • Persistent fault codes or a dead diagnostic LED.
  • Erratic short-cycling or random shutdowns not traced to other components.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS303HFAA0AAAA — OEM 1183618 Furnace Control Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS303HFAA0AAAA — OEM 1183618 Furnace Control Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS303HFAA0AAAA — OEM 1183618 Furnace Control Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.