Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS300SREA0AAAA — OEM 1183618 | Ships Today
ICP

ICP Control Board Kit for RGS300SREA0AAAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM control board kit (ICP part number 1183618) for the ICP / Tempstar / Heil RGS300SREA0AAAA furnace. The integrated furnace control board is the brain of the system — it manages the ignition sequence, monitors safety devices, sequences the inducer, igniter, gas valve, and blower, and reports fault codes through its diagnostic LED. When the board fails, symptoms range from a completely dead furnace to erratic operation, blower or inducer that will not run, repeated lockouts, or flashing diagnostic codes. Because it ties every furnace function together, always confirm the failure with diagnostic codes and basic checks before replacing the board. This kit supplies the OEM board and the hardware needed for installation.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Includes Control board and mounting hardware
Application Gas furnace control

Compatibility

Fits the ICP / Tempstar / Heil RGS300SREA0AAAA and related ICP-family furnaces specifying OEM control board kit 1183618. Confirm the board part number and connector layout match your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the control board.
  3. Document — Photograph every connector and wire harness position before disconnecting; this is critical for a multi-connector board.
  4. Remove — Unplug each harness, remove the board mounting screws or standoffs, and lift out the old board.
  5. Install — Mount the new board, then reconnect every harness to the matching connector per your photos.
  6. Test — Restore power and verify a normal startup sequence — inducer, igniter, flame, then blower — with no fault codes.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED
  • Repeated lockouts or erratic, inconsistent operation
  • Blower or inducer will not run despite good components
  • Persistent or nonsensical fault codes after other parts check out

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SREA0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SREA0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SREA0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online