This genuine OEM control board kit (part #1183618) for the ICP/Tempstar/Heil RGS300SDFA0AAAA is the furnace's integrated ignition control — the brain that manages the entire heating sequence. It sequences the inducer, igniter, gas valve, and blower; monitors safety inputs such as limit switches, pressure switches, and the flame signal; and protects the system through timed trials for ignition and safe lockouts. When the board fails, the furnace may not respond to the thermostat, may lock out repeatedly, may fail to energize the igniter or blower, or may run erratically. Supplied as a kit for a complete, correct replacement, this OEM board restores reliable, code-compliant operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition & Sequence Control
Fit OEM

Compatibility

Engineered for the ICP RGS300SDFA0AAAA and shared across the Tempstar, Heil, Comfortmaker, and International Comfort Products furnace families that use this control. Confirm part number 1183618 against your existing board before ordering, and verify any kit revision instructions included.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to reach the control board.
  3. Document — Photograph every wire harness and terminal connection before disconnecting.
  4. Remove — Unplug the harnesses, transfer connections, and unfasten the old board from its standoffs.
  5. Install — Mount the new board on the standoffs and reconnect each harness to the matching terminal per your photo and the kit instructions.
  6. Test — Restore power, call for heat, and confirm the full sequence: inducer, ignition, flame proof, and blower.

Signs You Need a Replacement

  • Furnace does not respond to the thermostat
  • Repeated ignition lockouts or error codes on the board LED
  • Igniter, inducer, or blower fails to energize in sequence
  • Erratic operation or no heat despite good upstream components

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300SDFA0AAAA — OEM Ignition | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300SDFA0AAAA — OEM Ignition | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300SDFA0AAAA — OEM Ignition | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online