Overview

This genuine OEM control board kit (part number 1183618) is the furnace ignition control for the ICP / Heil / Tempstar RGS300LREA0AAAA. The control board is the brain of the furnace — it sequences the ignition cycle, energizes the inducer and igniter, opens the gas valve, monitors flame and limit safeties, and controls blower timing. When the board fails, you may see no response to a heat call, erratic blower behavior, repeated lockouts, or blinking diagnostic LED fault codes that point to a control problem. This kit ships with the matched OEM board and the hardware needed for a clean swap, restoring proper ignition sequencing and safety monitoring.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Ignition Control Board Kit
Brand ICP (Heil / Tempstar)
Function Ignition Sequencing, Blower & Safety Control
Application Gas Furnace

Compatibility

Direct-fit OEM replacement for the ICP / Heil / Tempstar RGS300LREA0AAAA and shared furnace platforms that use control board kit 1183618. Verify your existing board's part number and connector layout before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every harness connection and note any DIP switch or jumper positions before disconnecting.
  4. Remove — Unplug all connectors and remove the board mounting screws or standoffs.
  5. Install — Mount the new board, transfer DIP/jumper settings to match, and reconnect each harness per your photos.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • No response from the furnace on a call for heat.
  • Blinking diagnostic LED showing a control or ignition fault.
  • Repeated lockouts even with a good igniter and flame sensor.
  • Erratic blower operation or burned/scorched spots on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300LREA0AAAA — OEM Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300LREA0AAAA — OEM Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300LREA0AAAA — OEM Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.