This OEM control board kit (part 1183618) is the brain of your ICP RGS300HEFA0AAAA gas furnace. It sequences the entire heat cycle — proving the inducer, energizing the igniter, opening the gas valve, monitoring flame, and timing blower on/off — while watching limit and pressure safeties throughout. The kit ships with the board and the hardware needed for a clean swap. Board failures show up as a furnace that does nothing on a call for heat, blinking diagnostic LED fault codes, the blower running constantly, or intermittent operation. Power surges, moisture, and aging relays are the typical culprits.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, Blower & Safety Control
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS300HEFA0AAAA. Match the OEM kit number to your unit's parts list — control boards are model-specific, so verify the part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and switch, then verify zero voltage with a multimeter.
  2. Access — Remove the control compartment service panel.
  3. Document — Photograph every connector and wire position before disconnecting; boards have many similar plugs.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift the old board out.
  5. Install — Seat the new board, then reconnect each harness to the matching terminal per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No response from the furnace on a call for heat.
  • Diagnostic LED flashing hard-fault codes.
  • Blower runs constantly or fails to start.
  • Intermittent ignition, lockouts, or scorched spots on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS300HEFA0AAAA — Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS300HEFA0AAAA — Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS300HEFA0AAAA — Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.