Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS244HSAA0AAAA gas furnace. The board is the brain of the appliance — it manages the ignition sequence, blower and inducer timing, safety lockouts, and 24V signaling between the thermostat, gas valve, igniter, and limit switches. When a control board fails, the furnace may fail to ignite, short-cycle, run the blower continuously, or flash a diagnostic fault code on the onboard LED. Replacing the board with the exact OEM kit restores factory timing and protects downstream components.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24V
Fitment OEM Direct Replacement
Diagnostics Onboard LED fault code

Compatibility

Designed as a direct OEM replacement for the ICP Tempstar Heil RGS244HSAA0AAAA furnace and related RGS-series models that originally shipped with control 1183618. Always verify the printed part number on your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the existing board before disconnecting.
  4. Remove — Unplug the wiring harnesses, release the board mounting standoffs/screws, and lift out the old control.
  5. Install — Seat the new board on the standoffs and reconnect each harness exactly per your photos.
  6. Test — Restore power, initiate a heat call, and confirm proper ignition, blower, and inducer operation with no fault codes.

Signs You Need a Replacement

  • Furnace will not start or fails to begin the ignition sequence
  • Blower or inducer motor runs constantly or never starts
  • Onboard diagnostic LED flashes a hard-lockout fault code
  • Intermittent short-cycling or no response to the thermostat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HSAA0AAAA — OEM Integrated Furnace Control 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HSAA0AAAA — OEM Integrated Furnace Control 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HSAA0AAAA — OEM Integrated Furnace Control 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online