Overview

This is the genuine OEM control board kit (part number 1183618) for the ICP / Tempstar / Heil RGS244HRFA0AAAA gas/electric package unit. The integrated furnace control board is the brain of the heating section: it manages the ignition sequence, monitors safety limits and pressure switches, controls the inducer and blower motor timing, and coordinates the call for heat from the thermostat. When this board fails, the unit may not ignite, may short-cycle, may run the blower continuously, or may go completely dead with no response to a thermostat call. Common failure symptoms include flashing diagnostic LED fault codes, no inducer or igniter activity on a heat call, blown low-voltage fuses, and intermittent operation as solder joints crack from thermal cycling. Replacing the board with the exact OEM kit restores correct ignition timing and all factory safety logic.

Specifications

Spec Value
Part Number 1183618
Description Kit, Control Board
Type Integrated Furnace Control (IFC)
Brand ICP / Tempstar / Heil
Control Voltage 24V low-voltage
Fitment OEM direct replacement
Model RGS244HRFA0AAAA

Compatibility

Designed as a direct-fit replacement for the ICP-family RGS244HRFA0AAAA gas/electric package unit and is shared across closely related Tempstar, Heil, and Comfortmaker package units that use the 1183618 control kit. Always confirm the printed part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control/blower access panel.
  3. Document — Photograph every wire and connector position on the existing board before disconnecting.
  4. Remove — Unplug the molex connectors and individual terminals, remove the mounting screws or standoffs, and lift out the old board.
  5. Install — Mount the new board on the same standoffs and reconnect every wire exactly per your photo.
  6. Test — Restore power, initiate a heat call, and confirm a normal ignition sequence and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No ignition sequence — inducer and igniter never energize on a heat call.
  • Flashing or steady fault-code LED indicating a board failure.
  • Blower runs continuously or never starts.
  • Repeated blown low-voltage fuses or intermittent dead unit.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS244HRFA0AAAA Gas/Electric Package Unit | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS244HRFA0AAAA Gas/Electric Package Unit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS244HRFA0AAAA Gas/Electric Package Unit | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.