Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Control Board Kit for RGS243LTFA0AAAA – Furnace Ignition Control | Ships Today
ICP

ICP Control Board Kit for RGS243LTFA0AAAA – Furnace Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (OEM part 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS243LTFA0AAAA gas furnace. The board is the brain of the furnace: it manages the ignition sequence, sequences the inducer and blower motors, monitors the limit and pressure switches, drives the gas valve, and runs continuous flame-sense safety and diagnostic logic. Voltage spikes, flame-sensor feedback faults, cracked solder joints, and burned relays all cause board failure. Symptoms range from a completely dead furnace to short cycling, no inducer or blower, or flashing diagnostic LED fault codes. This kit ships with the replacement board and mounting hardware so you can restore full, safe operation in a single service call.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Function Ignition, Blower & Safety Control
Diagnostics LED Fault Code Indicator
Fit OEM Direct Replacement Kit

Compatibility

Designed for the ICP RGS243LTFA0AAAA and shared across compatible ICP-family RGS-series gas furnaces sold under Tempstar, Heil, Comfortmaker, and Arcoaire. Match the board part number, connector layout, and harness plugs to your existing control before installing.

Installation Guide

  1. Safety First – Disconnect furnace power and shut off gas; verify zero voltage with a multimeter.
  2. Access – Remove the furnace control/blower access panel.
  3. Document – Photograph every harness plug and terminal location before disconnecting.
  4. Remove – Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install – Mount the new board, then reseat every connector firmly in its matching position per your photo.
  6. Test – Restore gas and power, call for heat, and confirm a full ignition cycle with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to a heat call
  • Inducer or blower fails to start or runs continuously
  • Flashing diagnostic LED fault code at the board
  • Visible burn marks, corrosion, or scorched relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243LTFA0AAAA – Furnace Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243LTFA0AAAA – Furnace Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243LTFA0AAAA – Furnace Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera