This OEM control board kit (part 1183618) is the brain of the ICP RGS243HREA0AAAA, managing the entire heating and blower sequence. It reads the thermostat call, sequences the inducer, energizes the igniter, opens the gas valve, monitors flame and safety switches, and controls blower timing. When the board fails, the symptoms can mimic almost any other component — no ignition, no blower, intermittent operation, or repeated lockouts with no clear cause. Burnt relays, scorched traces, blown onboard fuses, and dead diagnostic LEDs all point to a board at the end of its life. This factory kit includes the board and the hardware needed for a clean direct replacement, restoring correct sequencing and safety monitoring.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Control
Fit OEM Direct Replacement

Compatibility

Direct-fit OEM replacement kit for the ICP/Tempstar/Heil RGS243HREA0AAAA and related RGS243 series units using the factory integrated control board.

Installation Guide

  1. Safety First — Disconnect power and shut off the gas; verify zero voltage with a multimeter.
  2. Access — Remove the control compartment panel.
  3. Document — Photograph every wire harness and connector before disconnecting.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and transfer each harness to its matching terminal per your photos.
  6. Test — Restore gas and power, then confirm a full heat cycle and correct blower operation; check the diagnostic LED for fault codes.

Signs You Need a Replacement

  • No response to the thermostat with power present
  • Burnt relays, scorched traces, or a blown onboard fuse
  • Intermittent operation or random lockouts
  • Diagnostic LED dark or flashing a hard-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS243HREA0AAAA — OEM Furnace Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS243HREA0AAAA — OEM Furnace Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS243HREA0AAAA — OEM Furnace Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online